How to install rj-45 connector onto the cable




















Activate JavaScript to see the email. Digital Aerials. I think that you have come to the right place, but you may not yet. To make life as easy as possible for you I have tried to create our site which shows us to the best of our ability. What to expect from our service, how we differ from the rest and how using us can actually benefit you! Checking the Physical View of the Metal Contact Slices The checking standards are listed as follows: The metal contact slices should be of the same height and are of the required sizes.

The crimp part should properly contact the core conductor. The metal contact slices should be basically parallel with a deviation of not more than five degrees. The top edges should be basically parallel with the axes of the RJ45 connector with a deviation of not more than 10 degrees.

This ensures reliable contact. No perceptible object, dirt or rust should be present on the surface of the metal contact slice. Otherwise, the conductivity is affected. The metal contact slices should reliably contact the RJ45 connector socket.

The plastic spacers should remain the same before and after the crimping, and should have the same spacing between each other. Each of them should be straight and intact. The crimping blade of the metal contact slice should exceed the core end. The core end should tightly contact the trunking side of the RJ45 connector. The contact spacing should not exceed 0.

Procedure Hold the crimped RJ45 connector and observe the side from the front. Check the height of each metal contact slice. The standard height is 6. If no special test instrument is available on site, compare the RJ45 connector with another well crimped RJ45 connector. Figure and Figure show an unqualified RJ45 connector and a qualified RJ45 connector respectively.

Figure Metal contact slices of inconsistent height. Figure Metal contact slices of consistent height. Prerequisites During the process of routing or bundling cables, and assembling the connectors, the circuit on the cable may become open or broken. Tools, Equipment and Materials Network cable tester Assembled network cable. Background Information You can also use a multimeter to test the connectivity of the network cable according to the core connections.

Procedure Insert the RJ45 connectors at the two ends of the assembled network cable into the RJ female ports of the network cable tester in sequence. Make sure the RJ45 connectors are inserted properly. Turn on the network cable tester and start the test.

In the case of the crossover cable and straight through network cable, the test procedures are the same but the indicators at the two ends turn on in different sequences. Therefore, RJ45 connectors are larger than RJ11 connectors in forms. An RJ45 connector is usually used for data transmission in scenarios such as monitoring projects and general cabling in the equipment room.

It is an indispensable supporting role in Ethernet and is generally used at both ends of a network cable to connect various network devices, such as computers, routers, switches, etc. Notice: Due to the different structure of RJ45 and RJ11 connectors, the wiring sequence standard and applications are also different.

It is not recommended to use RJ11 plugs for RJ45 jacks as it may cause damages on the devices. There are two types of twisted pair cables according to the RJ connectors. Stranded-conductor twisted-pair cable is made up of many tiny hairlike strands of copper twisted together into a larger conductor. These conductors have more surface area to make contact with but are more difficult to crimp because they change shape easily.

Because of their difficulty to connect, they are usually used as patch cables. Most UTP cable installed in the walls and ceilings between patch panels and wall plates is solid-conductor cable. Although they are not normally used as patch cables, solid-conductor cables are the easiest to connect, so many people make their own patch cords out of solid conductors.

There are mainly three tools which are needed in the coming installation. The first tool is a cable-jacket stripper. It will only cut through the outer jacket of the cable, not through the conductors inside. Many different kinds of cable strippers exist, but the most common are the small, plastic ones that easily fit into a shirt pocket. I learned this the hard way! To continue this discussion, please ask a new question.

Get answers from your peers along with millions of IT pros who visit Spiceworks. Best Answer. Justin This person is a verified professional. Verify your account to enable IT peers to see that you are a professional. I have a box of Tough connectors from Ubiquiti for my outdoor cable. View this "Best Answer" in the replies below ».

Popular Topics in General Networking. Spiceworks Help Desk. The help desk software for IT. Track users' IT needs, easily, and with only the features you need. Learn More ». Colts This person is a verified professional. Well, yes.. Go to your local Electrical Supply dealer, and ask them.

Outdoor cable also has gel on the inside to 'weather proof' the connections. Pictuelle Nov 5, at UTC. Maybe something like this - It grabs the outside of the cable and your RJ45 Jack just pinches the wire like you already have -??

That's the fun part! Justin wrote: I have a box of Tough connectors from Ubiquiti for my outdoor cable. This appears to be the best solution!